Cabling Factor

In: Computers and Technology

Submitted By jlindsay14
Words 355
Pages 2
When performing a cable installation there is certain factors which need to be addressed prior to starting your design. Planning is one of the most important aspects or a proper design for your installation. Deciding where your cables are going to be ran what equipment you’re going to need to set up the network system. What tools you’re going to need to achieve the desired outcome and materials.
Also, making sure the area you are going to be installing in is up to NFPA, FCC, UL, NEC code. Verifying that a system is safe from harming any occupants that may inhabit the structure is key to quality and control. Also if your equipment is safe and of good quality not only will your system be safe but also run better. If you have wires hanging out, shorts in networking hardware, systems that run too hot and placed in tight areas with no ventilation just some examples.
Some aspects of proper design are having a detailed plan of how the installation will proceed, you should know the scope of the project, and i.e.…how many cable runs you have what connections need to be made. Your design should also be made available to all people involved with the installation. As well as contain a blueprint of how the cables will be installed.

Tools that will be useful in your installation will be, Wire cutters, crimpers, pen and paper, fish tape, pull string, two way radio, labeling materials, punch down tool, toning tools, basic hand tools.
I know I have used off the book tools to install cabling. One of the tools I used and it actually stays in the wall is a small plastic funnel. It actually keeps the cable from bending when not going through the back side of the wall. When you cut your spot out where you’re placing your connection box place a small funnel with the cone side in and pull the cable through that actually allows the cable to make a gentle right or left turn rather than…...

Similar Documents

Cabling Notes

...Notes What is the speed of light- 186000miles a second or 700 million miles an hours?How fast dose sound travel.-340mdHow fast dose sound travel in water -33502mph | Cabling Notes 6/20/12 Name three rules of Data cabling 1. Networks never get smaller or less complicated. 2. Don’t scrimp on installation cost. Quality components and cable must be installed, No poor workmanship allowed. 3. Plan for higher –speeds technologies than are commonly available today. Just because 1000Base-TEthernet seems unnecessary today doesn’t mean in five years you will need to use it. The cost of poor cabling – The cost that results from poorly planned and poorly implemented cabling systems can be staggering. Robert Metcalfe (Inventor of the Ethernet, founder of 3Com, columnist for InfoWorld, and industry pundit). Drop-rate magnification-The high degree of network problems caused by dropping a few packets. Note: a single dropped packet may cause an entire stream of packets to be retransmitted. ANSI-(American National Standards.) Application- a program on a computer. A system, the transmission method of which is supported by telecommunications cabling, such as 100Base-TX Ethernet, or digital voice. Digital- on the other hand is breaking the signal into a binary format where the audio or video data is represented by a series of "1"s and "0"s. Simple enough when it's the device—analog or digital phone, fax, modem, or likewise—that does all the converting for...

Words: 910 - Pages: 4

Lab9 Cabling

...required network cabling, termination points/boxes and necessary network devices. Mating sleeves, bare fiber adapters and optical attenuators are a few things that are needed specifically for fiber installation. In addition, the purpose would also include the proper details and criteria for the successful design of the network system. The contractor shall provide all of the necessary cables, network equipment and components necessary to construct the network system. This includes all raw materials such as cable, wall plates, outlet boxes, and such terminating modules and components as necessary to complete the job as contracted. Devices like test kits, power meters, fault locators, and connector adapters are all pre purchased and is property of the installing company. This document provides all of the necessary specifications to be used in the design of the network infrastructure and associated equipment. The contractor shall furnish all labor, materials, tools, equipment and reasonable incidental services necessary to complete an acceptable installation of the network infrastructure as contracted. Business Case Your network will be FTTB (Fiber to the Building). This means that the fiber will run to the main building and that will give you the ability to use fiber throughout the entire complex or the use of high-bandwidth copper cabling can be used. For the wired portion of the building and the telecommunications room, we will be using 62.5/125 cabling. Each room......

Words: 1246 - Pages: 5

Cabling Factors and Tools

...Alicia Kennedy Unit 5 assignment 1 When performing a cable installation there are a lot of things that you have to put into consideration. You want to draw up a plan first and some things that you would want to include in the plan would be where your telecommunications rooms are located, What is the distance from your leased line to your core router, and what type of cable are you going to be using for your backbone and horizontal lines. The first thing shouldn’t be cost when you are designing a network. You want to think of the safety and how your network will function with different mediums of cable. This things are important because your network to meet the needs of the company. You also want to make sure you have things in place like what type of fire protection your network will have. You want to make sure your racks in your telecommunication rooms are grounded properly. Without these things your network will not be very safe. You want it to be useful but you don’t want to lose everything in a telecommunications room because you failed to plan ahead for accidents that can happen. Well once you have your plan intact and it has been approved you need to think about how you are going to get this cable in the building. What types of tools are you going to need? If you are going to run CAT 5e though out the building you will need several different tools; such as cable pulleys, punch downs, wire cutters, and cable strippers. You will need most of these tools to install......

Words: 480 - Pages: 2

Cabling Assignment 1

...the end users’ requirements and specify products that will support them. Since you must ensure that the product is specified per recognized U.S. industry standards, you will be careful to identify that the customer request references the appropriate application and cabling standards. What industry standards body and standards series numbers do you need to reference for Ethernet applications and cabling? The IEEE maintains the industry standards for Ethernet protocols (or applications). This is part of the 802.3 series of standards and includes applications such as 1000Base-T, 1000Base-SX, 10GBase-T, and 10GBase-SR. 2. An end user is interested in ensuring that the network cabling they install today for their 1000Base-T network will be able to support future speeds such as 10Gbps to a maximum of 100 meters. They have heard that Category 6 is their best option. Being well versed in the ANSI/TIA-568-C standard, you have a different opinion. What are the different types of Category 6 cable and what should be recommended for this network? There is the Cat 6 and Cat 6A and Category 6A would be recommended for the network since it was intended for 10Gbps networking. 3. Your customer is installing communications cabling in a factory full of stray EMI. UTP is not an option and a shielded cable is necessary. The customer wants to ensure capability to operate at 10GBase-T. What cable would you recommend to offer the best shielding performance? The best possible cable would be......

Words: 546 - Pages: 3

Unit 5 Assignment 1 Cabling Factors and Tolls Discussion

...Unit 5 Assignment 1 Cabling Factors and Tolls Discussion Flexibility What type of install is the cable going into? Is everything in a fixed position? If you have an install where items are moved around without being disconnected, using highly flexible cable is necessary. Cables in these scenarios need to be flexible to meet those demands of mobility, and also for the life of the wire so that it does not crack, break, fray or short. We had a job at a university where we moved flat panels on a track system to create different screen sizes, and for that we had to make sure the cable would meet the demand. Capacitance Cat 6 is not always better than Cat 5. If a video extender is made for Cat 5e, using Cat 6 may cause you a problem. The electrical properties are different, and the circuitry inside may not be able to reconcile the increased capacitance. You should confirm with the manufacturer before making a substitute in a Category cable. Jacket What type of jacket does your cable need? You have plenum, riser, PVC/non-plenum and direct burial. Plenum cable is often required in commercial work, especially in buildings where there are open-air returns; it is essential to meeting code. Integrators will often use riser grade at the riser, and then transfer to plenum in the plenum space. This saves some cost, but I recommend you second-guess saving that few cents per foot in most cases. The chances of mixing up a box of cable and pulling riser in the plenum space may......

Words: 318 - Pages: 2

Cabling Factors and Tools Discussion

...Cabling Factors and Tools Discussion When performing cable installations there are three factors that need to be considered, fire protection, water intrusion or flood protection, or changes in the structural foundation in your home. The two most important considerations to take into account when either pre-wiring a house or wiring after the house is complete, are the routing of the cable and the quality of the wire used. These two points are often overlooked and the decision to wire the house at all often comes as an afterthought, when most if not all of the interior of the structure has been completed. Pre-wiring your house, or installing the wire in the stage of construction just before the drywall goes on, is always the preferred method and offers the most flexibility in placement of outlets and the routing of your cable .When deciding on the location of your outlets, try to visualize where you'll eventually be placing the furniture in the room in relation to the location of your television. Internet services are also being provided now by a lot of cable companies so placing an outlet in a spot near your planned computer station is also a good idea .In general it's a good idea to put at least one outlet in every room whether or not you plan to use it immediately. At least it will be there when it is needed, avoiding the drilling of any unsightly holes in the future. Outlet boxes can be purchased at any hardware store and should be fastened to the wall stud in the......

Words: 988 - Pages: 4

Cabling

...   271  Q: A. What are the common wavelengths of operation for multimode fiber? Ans:   850 and 1300 NM   Q; B. What are the common operating wavelengths of single-mode fiber? Ans:   1300, 1490, 155NM  Q; A. What are the key advantages of fiber-based systems?    Ans:   The typical advantage is immunity to electromagnetic interface, higher data rates, longer maximum distance and better security   B.   Based on these advantages, in which applications would you use fiber instead of UTP copper? Ans:   Fiber should be used instead of copper when the application requires an application speed to deliver a signal over a distance quarter than 100 meters and when better security and resistance to EMI are critical operating factors...

Words: 256 - Pages: 2

Cabling

...What industry standards body and standards series numbers do you need to reference for Ethernet applications and cabling? a. The Commercial Building Telecommunications Cabling Standard, known as ANSI/TIA/EIA-568-C. b. The IEEE maintains the industry standards for Ethernet protocols, which is part of the 802.3 series of standards. There is an increased need for speed these days and network technology designers are planning to support data rates of up to 100Gbps. 2. What are the different types of Category 6 cable and what should be recommended for this network? a. 10Gbps @ 100 Meters – There are two types of Category 6 cable, regular Category 6, and Category 6A (or Augmented Category 6). It would be my recommendation to use 6A or Category 7. Since we have to support 10Gbps over a maximum of 100 meters, I would recommend using Category 6A, or Category 7 cabling. 3. What cable would you recommend to offer the best shielding performance? a. Full of stray EMI, UTP not an option, and customer wants to ensure capability to operate at 10GBase-T. i. I could recommend a Screened Twisted-Pair Cable or Screened Shielded Twisted-Pair Cable. 4. What type of cable would you use for a. Horizontal Spaces – Plenum cables. Solid Conductor Wire. b. Vertical Spaces – You should use riser-rated cabling in vertical spaces or where flexibility is important. Stranded-conductor wire. 5. What would you look for in trying to find fault if you had the following failures: a. NEXT and......

Words: 341 - Pages: 2

Unit 5 Cabling Factors

...4/14/2014 Unit 5. Assignment 1: Cabling Factors and Tools Discussion Three factors that need to be considered is being fire protected, water proof, and shock protection. Being fire protected, just in case a fire occurs, the wiring would be protected by a casing around the actual wires which in cause wouldn’t melt the casing and destroy the wires. Since the data room is usually in the basement of companies, if a flood occurs, there are wires that are protected by a casing that would not let water intrude into the casing. For shock protection, there is always a chance for a shortage to happen. Wiring and a lot of electricity used. For example, if there is a storm going on and lightning hits a generator and shorts everything out, it would not fry the wiring if they are protected from the shock. The two most important considerations to take into account when either pre-wiring a house or wiring after the house is complete, are the routing of the cable and the quality of the wire used. These two points are often overlooked and the decision to wire the house at all often comes as an afterthought, when most if not all of the interior of the structure has been completed. Some tools that would be useful to use are cable cutters, hole cutting tools, wire strippers, punch down tools, RJ45 connector crimp kits, pliers and cutters, label makers and electrical tape. The makeshift tool that we would use is a staple gun....

Words: 256 - Pages: 2

Cabling Definitions

...Montie Ramsarran July 7th, 2014 N1T1310 Mr. Amos Unit 4. Exercise 1. Cabling-Definitions. 1. Horizontal Cable-The cabling between and including the telecommunications outlet and the horizontal cross-connect. Horizontal cabling is considered the permanent portion of a link; may also be called horizontal wiring. 2. Backbone Cable-A cable connection between telecommunications or wiring closets, floor distribution terminals, entrance facilities, and equipment rooms either within or between buildings. This cable can service voice communications or data communications. In star-topology data networks, the backbone cable interconnects hubs and similar devices, as opposed to cables running between hub and station. In a bus topology data network, it is the bus cable. Backbone is also called riser cable, vertical cable, or trunk cable. 3. Patch Cords-Any flexible piece of cable that connects one network device to the main cable run or to a patch panel that in turn connects to the main cable run; also called. Used for interconnecting circuits on a patch panel or cross-connect. Patch cables are short distance, usually have connectors preinstalled on both ends, are used to connect equipment, and are generally between 3 and 6 meters long. 4. Connectors-With respect to cabling, a device attached to the end of a cable, receiver, or light source that joins it with another cable, device or fiber. A connector is a mechanical device used to align......

Words: 1141 - Pages: 5

Cabling

...applications and cabling? A # 1) The IEEE sustains the industry standards for Ethernet applications and cabling. This is a segment of the 802.3 series of standards and includes applications such as 1000Base-T, 1000Base-SX, 10GBase-T, 10GBase-SR. I found the answer on page 8 in Cabling: The Complete Guide to Copper and Fiber-Optic Networking 4th Edition book. Q # 2) What are the different types of Category 6 cable and what should be recommended for this network? A # 2) Only two different types of 6 cables Category 6, 250 MHZ and Category 6A, 500 MHZ. I would recommend for this network the Category 6A because it has a higher MHZ and as well the network intended to use 10 GB Ethernet with a bandwidth support of 500 MHZ is better than 250MHZ support. The reason I recommend this because of the information on page 8, 12, 17, and 35 in the Cabling: The Complete Guide To Copper and Fiber-Optic networking 4th Edition Book. Q # 3) What Cable would you recommend to offer the best shielding performance? A # 3) I would recommend the S/STP cabling, also known as screened fully shielded twisted – pair (S/FTP), Contains four individually shielded pairs of 24,AWG, 100 ohm wire surrounded by outer metal shielding covering the entire group of shielded copper pairs. This type of cabling offers the best protection from interference from external sources, and also eliminates alien crosstalk, allowing the greatest potential for higher speeds. Sited from page 14 from Cabling: The Complete......

Words: 675 - Pages: 3

Cabling Factors

...Clarence Gilchrest 10/06/2014 EN1320 Introduction Over ten years ago, I claimed victory at graduation vowing to never enter a classroom again. Didn’t take long for another battle to begin without my awareness, forcing me to break my vow. It was probably a foolish vow to begin with anyway. But even after doing so, starting school again, I didn’t get very far. So what was all that for? Why did I go through that to make a noble decision only just to fail? I consider myself as a late bloomer, though I was given a heads-up on the new world I was entering, I still didn’t get until I was in it. Getting as much advice from wiser people as possible still didn’t give me enough common sense to go out and follow that advice given. Whoever had that problem? How were you able to break it? Now I’m back at that same decision I made all those years ago, and I feel so much different from before. What happened? What changed? What gave me this confidence and courage repeat what I failed in the past? Everyone experiences life similarly but differently. This introduction only will attract those who may have had the same thought process as my own. This is a reflection of personal issues with oneself, and who is willing to break these weaknesses by any means. This is not a guideline for I can’t tell anyone how run their life. This is for you to take a pencil and paper and write down any relevant notes that you feel may help you in your process of becoming a stronger person. This is only......

Words: 286 - Pages: 2

Cabling

...The IEEE (Institute of Electrical and Electronics Engineers) maintains the industry standards for Ethernet protocols. The 802.3 series includes Ethernet applications and cabling. The different types of category 6 cable includes CAT6, CAT6A, and CAT6E, although 6E is not an industry recognized standard. I would recommend CAT6A for the possible 10GBASE-T upgrade in the future because it has improved alien crosstalk characteristics when compared to regular CAT6. Unless you decided to go with fiber, you should use STP CAT 6a or CAT7 for a 10gbase-t network, although there were quite a few articles online arguing that shielded cable is unnecessary after going to cat6a or 7 due to higher frequencies that these cable can utilize. The horizontal spaces should use fire retardant plenum cable since it is also used for HVAC. While it might also be prudent to use fire retardant riser cabling for the vertical shafts as well, however if fire stops are placed in the risers you could get away with using regular UTP as well in some places if cost was an issue. The NEXT and FEXT problems could have something to do with having a cable with too many twists, with NEXT the problem would be at the end of the cable where the signal originates, and with FEXT it would be at the opposite end. As the signal rate increases alien crosstalk become more and more of an issue. If it is too much of an issue your best bet might be to upgrade to fiber....

Words: 255 - Pages: 2

Structured Cabling Homework 1

...Structured Cabling Unit 1 Homework Exercise 1.1 Master it 1. What industry standards body and standards series numbers do you need to reference for Ethernet applications and cabling? A: The IEEE is used as the standard for Ethernet applications and cabling. It is part of the 802.3 series of standards and includes applications such as 1000Base-T, 1000Base-SX, 10GBase-T, and 10GBase-SR. 2. What are the different types of category 6 cables and what should be recommended for this network? A: There are two types of category 6 cables, Cat-6 and Cat-6a I would recommend a Cat-6a for this network since its intended use is for 10 Gigabit Ethernet with a 500MHz bandwidth support. 3. What cable would you recommend to offer the best shielding performance? A: I would recommend a Cat-6a (STP Cable) for this project. My recommendation is based on this cables capability to protect the network from EMI and to operate at 10Base-T. 4. What type of cable would you use for the horizontal spaces and vertical links? A: As for the horizontal spaces, riser-rated cabling is more durable. However, for this project I would recommend a plenum cabling system to prevent toxic fumes if caught on fire. The client is planning to route the cable thought the same space used for air circulation and HVAC. For the Vertical links, I would recommend implementing a rise-related cabling to avoid fore to be spread between floors. “Plenum rated cables can be used in the riser, BUT riser cables cannot......

Words: 417 - Pages: 2

Cabling Standards

...INTRODUCTION TO STRUCTURED CABLING Compiled by Sonam Dukda Division of Information Technology Ministry of Communication September 2000 TABLE OF CONTENTS 1 2 INTRODUCTION .......................................................................................................................... 4 NETWORKING ............................................................................................................................. 5 2.1 Objectives ................................................................................................................................ 5 2.2 Choice of Software and Hardware........................................................................................... 5 3 NETWORKING TRENDS ............................................................................................................. 6 4 STANDARDS................................................................................................................................. 6 4.1 International Standards ............................................................................................................ 6 4.2 Industry Standards. .................................................................................................................. 6 4.3 Structured Cabling standards................................................................................................... 6 4.4 Highlights of the EIA/TIA-568A standards.................................................

Words: 5055 - Pages: 21

Windows KMS Activator Ultimate 2018 4 2 [CracksNow] | Suomi Script Font - 1 Font 80$ | United Kingdom